Maintenance
[Power Maintenance] Powerhouse 2 Breaker Maintenance - Rotterdam – January 29 through February 9, 2026

Dear Client,

We would like to notify you of upcoming power maintenance activities that will affect services in our Rotterdam datacenter. The power maintenance has been scheduled for January 29, 2026 through February 9, 2026.

Location: Rotterdam, The Netherlands

Schedule:

Date

Time (UTC)

Maintenance Work

January 29, 2026

06:00 - 16:00

The maintenance will be carried out on the generator and transformer breakers. Once the work is completed, there will be reduced redundancy. During transformer breaker maintenance, Powerhouse 1 will operate on generators. During the generator breaker maintenance, there will be reduced redundancy.

February 2 & 3, 2026

06:00 - 16:00

Maintenance will be performed on the UPS1 breakers. While this maintenance is in progress, generators will run in parallel with the power grid to provide continuity in the event of a grid failure, as UPS protection will not be available during this period.

February 4

06:00 - 16:00

Breaker maintenance on UPS2 will take place. Impacted customers will be notified separately..

February 5

06:00 - 16:00

Power impact may occur due to switching activities in the main panels.

February 6 & 9

06:00 - 16:00

Switching activities will take place in the main power distribution board in Powerhouse 1.

Planned impact: Reduced redundancy (see below for details)

Reason for this maintenance: Mandatory maintenance to ensure the safety, reliability and correct operation of our main power infrastructure.

Expected impact: Reduced redundancy: During the maintenance window, parts of the power infrastructure will be worked on one at a time which may temporarily reduce redundancy. Power will remain available throughout the maintenance and customers who may be affected will be notified separately.

Support: Our support department will be open during the maintenance. More details about how you can contact our support can be found here: https://www.i3d.net/support/

[Power Maintenance] UPS Replacement - Rotterdam – February 16, 2026

Dear Client,

We would like to notify you of upcoming power maintenance activities that will affect services in our Rotterdam datacenter. The power maintenance has been scheduled for February 16, 2026.

Location: Rotterdam, The Netherlands

Schedule: Start time: February 16, 2026, 06:30 UTC End time: February 16, 2026, 15:00 UTC Planned impact: No impact expected (see below for details)

Reason for this maintenance: The maintenance is a battery replacement with UPS1 and UPS2 in Powerhouse 2. The battery string where the work is being preformed on will be switched off and there will be a lower autonomy on the UPS. If needed the UPS will be set to Bypass and we will run the generators parallel to the grid.

Expected impact: No impact: No impact is expected during this work.

Support: Our support department will be open during the maintenance. More details about how you can contact our support can be found here: https://i3d.net/support/ You can find maintenance updates and the current situation at https://status.i3d.net/

Past Incidents

Tuesday 3rd, December 2024

No incidents reported

Monday 2nd, December 2024

US: Ashburn Backbone link between our Paris and Ashburn data centers down

At this moment, we are experiencing problems with: Backbone link between our Paris and Ashburn data centers.

The cause of the incident is currently: Unknown

We have taken the following actions to resolve the incident: We are currently monitoring the situation and are in touch with our vendor regarding status updates.

Estimated time of repair: Unknown.

Impact: Due to the current incident on our backbone link between our Paris and Ashburn data centers, users between these and surrounding regions may experience increased latency.

Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • This incident has been resolved.

  • SA: Johannesburg Backbone link between our London and Johannesburg data centers down

    At this moment, we are experiencing problems with: Backbone link between our London and Johannesburg data centers.

    The cause of the incident is currently: Unknown

    We have taken the following actions to resolve the incident: We are currently monitoring the situation and are in touch with our vendor regarding status updates.

    Estimated time of repair: Unknown.

    Impact: Due to the current incident on our backbone link between our London and Johannesburg data centers, users between these and surrounding regions may experience increased latency.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • This incident has been resolved.

  • Sunday 1st, December 2024

    No incidents reported

    Saturday 30th, November 2024

    No incidents reported

    Friday 29th, November 2024

    No incidents reported

    Thursday 28th, November 2024

    Backbone link between our Mumbai and Hong Kong data centers down

    At this moment, we are experiencing problems with: Backbone link between our Mumbai and Hong Kong data centers.

    The cause of the incident is currently: Maintenance

    We have taken the following actions to resolve the incident: We are currently monitoring the situation and are in touch with our vendor regarding status updates.

    Estimated time of repair: Until 2 december 23:59 UTC.

    Impact: Due to the current incident on our backbone link between our Mumbai and Hong Kong data centers, users between these and surrounding regions may experience increased latency.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • This incident has been resolved.

  • CH: Zürich Backbone link between our Milan and Zurich data centers down

    At this moment, we are experiencing problems with: Backbone link between our Milan and Zurich data centers.

    The cause of the incident is currently: Unknown

    We have taken the following actions to resolve the incident: We are currently monitoring the situation and are in touch with our vendor regarding status updates.

    Estimated time of repair: Unknown.

    Impact: Due to the current incident on our backbone link between our Milan and Zurich data centers, users between these and surrounding regions may experience increased latency.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • Our third party fiber provider informed us that the services are restored as of yesterday 03:44 UTC. The fiber team discovered that some fibers were damaged during the installation process of the cable. Our fiber provider informed us that this is a temporary fix and the permanent fix will be performed under a planned maintenance for which we will be duly notified.

  • Fiber cable damage during local gas pipe installation. Restoration works resume the next business day.

  • Wednesday 27th, November 2024

    No incidents reported

    Tuesday 26th, November 2024

    US: Chicago Backbone link between our Atlanta and Chicago data centers down

    At this moment, we are experiencing problems with: Backbone link between our Atlanta and Chicago data centers.

    The cause of the incident is currently: Unknown

    We have taken the following actions to resolve the incident: We are currently monitoring the situation and are in touch with our vendor regarding status updates.

    Estimated time of repair: Unknown.

    Impact: Due to the current incident on our backbone link between our Atlanta and Chicago data centers, users between these and surrounding regions may experience increased latency.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • This incident has been resolved.