Some systems are experiencing issues

About This Site

Welcome to the status page of i3D.net. Any known issues affecting any of our services will be tracked on this page. Potential impact may vary from customer to customer depending on the systems or services impacted.

All times used on this page will be in the UTC timezone.

You can subscribe to receive an email as soon as a status update has been published. You may consult our Privacy Statement for more information on the processing of your personal data.

Please reach out to our support team through our website or support@i3d.net if you have any questions or need help.

We are also available 24/7 by phone on the following phone numbers:

+31 (0)10 890 00 70

1-800-482-6910

Maintenance
[Power Maintenance] Generator Maintenance - Rotterdam – March 3, 2026

Dear Client,

We would like to notify you of upcoming generator maintenance activities that will affect services in our Rotterdam datacenter. The generator maintenance has been scheduled for March 3, 2026.

Location:

Rotterdam, The Netherlands

Schedule:

Start time: March 3, 2026, 07:30 UTC

End time: March 3, 2026, 10:30 UTC

Planned impact: Impact expected (see below for details)

Reason for this maintenance:

To ensure the proper functioning of our power infrastructure of our Rotterdam facility in the event of a power outage, our generators will undergo testing. We will be simulating a real power outage by switching off power to our phase monitoring systems.

Expected impact:

The lighting will briefly blink and there will be a short interruption on B-feed during the switchover to the emergency power. If everything is working correctly we will switch back when possible without extra interruption.

Reduced redundancy: As the generator control systems are switched to maintenance mode during the test run, auxiliary power redundancy is reduced during the maintenance window.

[Infrastructure Maintenance] Cooling Maintenance - Heerlen – March 23, 2026

We would like to notify you of upcoming cooling maintenance activities that will affect services in our Heerlen datacenter. The cooling maintenance has been scheduled for March 23, 2026.

Location:

Heerlen, The Netherlands

Schedule:

Start time: March 23, 2026, 07:00 UTC

End time: March 23, 2026, 16:00 UTC

Planned impact: Reduced redundancy (see below for details)

Reason for Maintenance:

We will perform preventive maintenance on the cooling systems to ensure continued reliability and safe operation.

Expected Impact: During the maintenance the cooling units will be maintained one by one. Cooling will remain available, but redundancy will be temporarily reduced while the work is carried out.

Support: Our support department will be open during the maintenance. More details about how you can contact our support can be found here: https://i3d.net/support/

Past Incidents

Friday 3rd, July 2020

No incidents reported

Thursday 2nd, July 2020

Website i3D.net i3D.net Website

At this moment we are experiencing problems with: the i3D.net website

The cause of the incident is currently: unknown

We have taken the following actions to resolve the incident: under investigation

Estimated time of repair: unknown

Impact: the i3D.net website is currently (partially) affected.

Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • This incident has been resolved, our website is fully operational again.

  • The cause of this incident has been found and a temporary fix has been implemented. We are working hard on a permanent solution.

  • Website Smartdc.net Smartdc Website

    At this moment we are experiencing problems with: the Smartdc website

    The cause of the incident is currently: unknown

    We have taken the following actions to resolve the incident: under investigation

    Estimated time of repair: unknown

    Impact: the Smartdc website is currently (partially) affected.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • This incident has been resolved, our website is fully operational again.

  • The cause of this incident has been found and a temporary fix has been implemented. We are working hard on a permanent solution.

  • Wednesday 1st, July 2020

    US: Ashburn Backbone link between our Ashburn and Dallas datacenters

    At this moment we are experiencing problems with: Backbone link between our Ashburn and Dallas datacenters

    The cause of the incident is currently: Fiber cut caused by a boring rig along a highway in San Marcos

    We have taken the following actions to resolve the incident: We are currently monitoring the situation and have reached out to our vendor for more information.

    Estimated time of repair: Unknown

    Impact: Some users may experience higher latency and/or packet loss on their connection to our Dallas, Chicago, Los Angeles and Ashburn facilities.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

  • The fibercut has been fully restored.

  • The Backbone Link is serving traffic again, but work has not been completed. ETR still unavailable.

  • The fibercut has been located and construction crews have been dispatched for repairs. No ETR at this time.

  • Our vendor has confirmed the issue to be a fiber cut caused by a boring rig along a highway in San Marcos. Due to the loss of this connectivity we are forced to re-route traffic elsewhere which may cause packet loss and/or added latency for users that are connecting to one of our following facilities: Los Angeles, Ashburn, Dallas and Chicago.

  • Tuesday 30th, June 2020

    SG: Singapore Backbone link between our St. Denis and Singapore datacenters

    At this moment we are experiencing problems with: Backbone link between our St. Denis and Singapore datacenters

    The cause of the incident is currently: Unknown

    We have taken the following actions to resolve the incident: We are currently monitoring the situation and have reached out to our Vendor for more information.

    Estimated time of repair: Recovered

    Impact: Due to the current ongoing incident on our backbone link between our St. Denis and Singapore datacenters, our Singapore datacenter has now become isolated from the i3D.net network. This might increase latency for users to our Singapore datacenter.

    Support: Our support department is available for more information and personal updates. New updates will be posted here. More details about how you can contact our support can be found here.

    Subscribe for the latest updates. You may consult our Privacy Statement for more information on the processing of your personal data.

    Monday 29th, June 2020

    No incidents reported

    Sunday 28th, June 2020

    No incidents reported

    Saturday 27th, June 2020

    No incidents reported